TP9A Petroleum Gauging Thermometer
HomeStore

TP9A Petroleum Gauging Thermometer

TP9A Petroleum Gauging Thermometer

MANY OTHER VERSIONS AVAILABLE. PLEASE CALL 800-390-0004 FOR PRICING ON MODELS NOT LISTED.  

(Please note - Thermoprobe products are built to the order and usually require 10 to 12 business days to ship)

The TP9A employs the proven RTD design that has been used in the TP7 and TP8 for many years. A sealed industrial quality overlay provides a user interface that is easy to use with gloves. A stainless steel enclosure protects the circuit board and large LCD from penetration by impact, water and reactive liquids.


The new TP9 circuit board is an evolutionary step up from our highly accurate, reliable and successful TL1 laboratory thermometer. The Power Button’s primary function powers the instrument for intervals of about 20 minutes since the last button was accessed. The Power Button can also be used to conserve power and clear the memory, or to make adjustment while in calibration mode. A simple menu operation is displayed by holding the Function Button, and alternately functions to allow adjustments in the calibration mode. Arrows on the left side of the display show the direction of the temperature reading and whether stability has been reached. At the user’s discretion stabilized temperatures can be logged at numerous liquid levels for a running average and later displayed for the user’s documenting purposes. But this feature never interferes with simply getting an accurate temperature reading.
To endure the environment and be intrinsically safe, the TP 9 is manufactured of materials, which are both immune to petrochemicals and are non-sparking. The enclosure is made of stainless steel. The probe assembly is constructed using non-stick cable and stainless steel sensor components.

Part Number Codes

  • SW  Standard Weight Sensor, 0.25 lb (0.11 Kg)
  •  EW  Extra Weight Sensor, 0.50 lb (0.23 Kg)
  •  AW  Asphalt Weight Sensor, 0.75 lb (0.34 Kg)
  •  RC  Railcar (NO) Weight Sensor, for railcar tank openings
  •  SM  Standard Cord Markings (5 ft)
  •  MM  Metric Cord Markings (1 M)
  •  NM  No Cord Markings
  •  Cord Length is in Feet except M, which is in Meters

Note that almost any combination of the codes may be ordered.  Please call for pricing if you don't see what you're looking for.

    Specifications

    Maximum Dimensions:

    10"L x 4.25"H x 6.4" W

    Probe

    304 Stainless Steel, Sealant, Aramid Fiber Reinforced, FEP or PFA
    Cable Jacket, Coaxial Construction

    Enclosure Material:

    Stainless Steel
    Acetal (Delrin) Probe Holder
    Polyvinylchloride Faceplate
    Stainless Steel Fasteners

    Batteries:

    2 AA Alkaline; Battery Life of approximately 200 hours
    Battery manufacturer’s battery operating temperatature range -4 to 130 °F, -20 to 54 °C
    Note: Battery may not provide adequate power if ambient temperature is extremely low or high.

    Temperature Accuracy:

    :

    Resolution 0.01
    Range: -40 to +400 °F
    -40 to +204 °C
    Calibrated Accuracy:
    ±0.2 °F from 32 to 200 °F
    ±0.5 °F from 200 to 400 °F
    ±0.1 °C from 0 to 100 °C
    ±0.3 °C from 100 to 200 °C
    4 Point NIST Traceable Report of Test
    Long-term drift not to exceed 0.05%/year
    Meets API requirements

    Specifications subject to change

    Select Versions
    From $492.41

    Original: $1,641.36

    -70%
    TP9A Petroleum Gauging Thermometer

    $1,641.36

    $492.41

    TP9A Petroleum Gauging Thermometer

    MANY OTHER VERSIONS AVAILABLE. PLEASE CALL 800-390-0004 FOR PRICING ON MODELS NOT LISTED.  

    (Please note - Thermoprobe products are built to the order and usually require 10 to 12 business days to ship)

    The TP9A employs the proven RTD design that has been used in the TP7 and TP8 for many years. A sealed industrial quality overlay provides a user interface that is easy to use with gloves. A stainless steel enclosure protects the circuit board and large LCD from penetration by impact, water and reactive liquids.


    The new TP9 circuit board is an evolutionary step up from our highly accurate, reliable and successful TL1 laboratory thermometer. The Power Button’s primary function powers the instrument for intervals of about 20 minutes since the last button was accessed. The Power Button can also be used to conserve power and clear the memory, or to make adjustment while in calibration mode. A simple menu operation is displayed by holding the Function Button, and alternately functions to allow adjustments in the calibration mode. Arrows on the left side of the display show the direction of the temperature reading and whether stability has been reached. At the user’s discretion stabilized temperatures can be logged at numerous liquid levels for a running average and later displayed for the user’s documenting purposes. But this feature never interferes with simply getting an accurate temperature reading.
    To endure the environment and be intrinsically safe, the TP 9 is manufactured of materials, which are both immune to petrochemicals and are non-sparking. The enclosure is made of stainless steel. The probe assembly is constructed using non-stick cable and stainless steel sensor components.

    Part Number Codes

    • SW  Standard Weight Sensor, 0.25 lb (0.11 Kg)
    •  EW  Extra Weight Sensor, 0.50 lb (0.23 Kg)
    •  AW  Asphalt Weight Sensor, 0.75 lb (0.34 Kg)
    •  RC  Railcar (NO) Weight Sensor, for railcar tank openings
    •  SM  Standard Cord Markings (5 ft)
    •  MM  Metric Cord Markings (1 M)
    •  NM  No Cord Markings
    •  Cord Length is in Feet except M, which is in Meters

    Note that almost any combination of the codes may be ordered.  Please call for pricing if you don't see what you're looking for.

      Specifications

      Maximum Dimensions:

      10"L x 4.25"H x 6.4" W

      Probe

      304 Stainless Steel, Sealant, Aramid Fiber Reinforced, FEP or PFA
      Cable Jacket, Coaxial Construction

      Enclosure Material:

      Stainless Steel
      Acetal (Delrin) Probe Holder
      Polyvinylchloride Faceplate
      Stainless Steel Fasteners

      Batteries:

      2 AA Alkaline; Battery Life of approximately 200 hours
      Battery manufacturer’s battery operating temperatature range -4 to 130 °F, -20 to 54 °C
      Note: Battery may not provide adequate power if ambient temperature is extremely low or high.

      Temperature Accuracy:

      :

      Resolution 0.01
      Range: -40 to +400 °F
      -40 to +204 °C
      Calibrated Accuracy:
      ±0.2 °F from 32 to 200 °F
      ±0.5 °F from 200 to 400 °F
      ±0.1 °C from 0 to 100 °C
      ±0.3 °C from 100 to 200 °C
      4 Point NIST Traceable Report of Test
      Long-term drift not to exceed 0.05%/year
      Meets API requirements

      Specifications subject to change

      Product Information

      Shipping & Returns

      Description

      MANY OTHER VERSIONS AVAILABLE. PLEASE CALL 800-390-0004 FOR PRICING ON MODELS NOT LISTED.  

      (Please note - Thermoprobe products are built to the order and usually require 10 to 12 business days to ship)

      The TP9A employs the proven RTD design that has been used in the TP7 and TP8 for many years. A sealed industrial quality overlay provides a user interface that is easy to use with gloves. A stainless steel enclosure protects the circuit board and large LCD from penetration by impact, water and reactive liquids.


      The new TP9 circuit board is an evolutionary step up from our highly accurate, reliable and successful TL1 laboratory thermometer. The Power Button’s primary function powers the instrument for intervals of about 20 minutes since the last button was accessed. The Power Button can also be used to conserve power and clear the memory, or to make adjustment while in calibration mode. A simple menu operation is displayed by holding the Function Button, and alternately functions to allow adjustments in the calibration mode. Arrows on the left side of the display show the direction of the temperature reading and whether stability has been reached. At the user’s discretion stabilized temperatures can be logged at numerous liquid levels for a running average and later displayed for the user’s documenting purposes. But this feature never interferes with simply getting an accurate temperature reading.
      To endure the environment and be intrinsically safe, the TP 9 is manufactured of materials, which are both immune to petrochemicals and are non-sparking. The enclosure is made of stainless steel. The probe assembly is constructed using non-stick cable and stainless steel sensor components.

      Part Number Codes

      • SW  Standard Weight Sensor, 0.25 lb (0.11 Kg)
      •  EW  Extra Weight Sensor, 0.50 lb (0.23 Kg)
      •  AW  Asphalt Weight Sensor, 0.75 lb (0.34 Kg)
      •  RC  Railcar (NO) Weight Sensor, for railcar tank openings
      •  SM  Standard Cord Markings (5 ft)
      •  MM  Metric Cord Markings (1 M)
      •  NM  No Cord Markings
      •  Cord Length is in Feet except M, which is in Meters

      Note that almost any combination of the codes may be ordered.  Please call for pricing if you don't see what you're looking for.

        Specifications

        Maximum Dimensions:

        10"L x 4.25"H x 6.4" W

        Probe

        304 Stainless Steel, Sealant, Aramid Fiber Reinforced, FEP or PFA
        Cable Jacket, Coaxial Construction

        Enclosure Material:

        Stainless Steel
        Acetal (Delrin) Probe Holder
        Polyvinylchloride Faceplate
        Stainless Steel Fasteners

        Batteries:

        2 AA Alkaline; Battery Life of approximately 200 hours
        Battery manufacturer’s battery operating temperatature range -4 to 130 °F, -20 to 54 °C
        Note: Battery may not provide adequate power if ambient temperature is extremely low or high.

        Temperature Accuracy:

        :

        Resolution 0.01
        Range: -40 to +400 °F
        -40 to +204 °C
        Calibrated Accuracy:
        ±0.2 °F from 32 to 200 °F
        ±0.5 °F from 200 to 400 °F
        ±0.1 °C from 0 to 100 °C
        ±0.3 °C from 100 to 200 °C
        4 Point NIST Traceable Report of Test
        Long-term drift not to exceed 0.05%/year
        Meets API requirements

        Specifications subject to change

        You may also like

        -70%NEW
        Thumbnail 1

        TL3A Precision Thermometer

        $1,102.47

        $330.74

        -70%NEW
        Thumbnail 1Thumbnail 2

        TP7D Series by ThermoProbe

        $1,665.21

        $499.56

        -70%NEW
        Thumbnail 1Thumbnail 2

        TL3 Precision Thermometer

        $377.19

        $113.16

        -70%NEW
        Thumbnail 1

        Temperature Probe Type K Fast Response

        $19.85

        $5.96

        -70%NEW
        Thumbnail 1

        IRTN408 Foodservice Infrared Thermometer

        $63.00

        $18.90

        -70%NEW
        Thumbnail 1

        35100-K Thermocouple Thermometer

        $277.77

        $83.33

        NEW
        Thumbnail 1

        1246-03-1 Bi-Metal Pocket Test Thermometer

        $8.61

        -70%NEW
        Thumbnail 1Thumbnail 2

        50360-K Cooper-Atkins Model 50360-K Oven Needle Probe

        $90.77

        $27.23

        -70%NEW
        Thumbnail 1

        3270-05 Kettle and Tank Deep Fry Thermometer

        $36.80

        $11.04

        NEW
        Thumbnail 1

        35100-J Thermocouple Thermometer

        $264.74

        -70%NEW
        Thumbnail 1

        93230-K Kit with 32311 Thermocouple Thermometer and 50336 DuraNeedle Probe

        $230.75

        $69.22