Our TR-5i Series data loggers are designed to measure and record temperature, voltage, 4-20mA, or pulse count. The body of the data loggers are water resistant and can be used in an environment of -40 °C to 80 °C. Moreover, battery-powered operation means the loggers can be placed anywhere without the need for AC power.
The data recorded by the loggers can be transfered to PC via separately sold "Communication Port TR-50U2" or "Data Collector TR-57DCi", whereby users can analyze the data and view in graph form.
Furthermore, our Data Collector TR-57DCi enables on-site data collection and viewing of data; no longer it is necessary to manually gather the data loggers.
The data recorded by the loggers can be transfered to PC via separately sold "Communication Port TR-50U2" or "Data Collector TR-57DCi", whereby users can analyze the data and view in graph form.
Furthermore, our Data Collector TR-57DCi enables on-site data collection and viewing of data; no longer it is necessary to manually gather the data loggers.
The TR-51i and TR-52i data loggers comply with EN12830, the European Standard regarding Temperature recorders for the transport, storage and distribution of chilled, frozen, deep-frozen/quick-frozen food and ice cream.
Specifications
| TR-51i | TR-52i | |
|---|---|---|
| Measurement Channels | Temperature 1ch (Internal) | Temperature 1ch (External) |
| Sensor | Thermistor | Thermistor |
| Measurement Units | °C, °F | °C, °F |
| Measurement Range | -40 to 80 °C | -60 to 155 °C |
| Responsiveness | Thermal Time Constant: Approx. 15 min. Response Time (90%): Approx. 35 min. |
Thermal Time Constant: Approx. 30 sec. (in air) Approx. 4 sec. (in agitated water) Response Time (90%): Approx. 80 sec. (in air) Approx. 7 sec. (in agitated water) |
| Accuracy | Avg. ±0.5 °C | Avg. ±0.3 °C [-20 to 80 °C] Avg. ±0.5 °C [-40 to -20 °C / 80 to 110 °C] Avg. ±1.0 °C [-60 to -40 °C/ 110 to 155 °C] |
| Measurement Resolution | 0.1 °C | |
| Logging Capacity | 16,000 readings | |
| Recording Interval | Select from 15 choices: 1, 2, 5, 10, 15, 20, 30 sec. or 1, 2, 5, 10, 15, 20, 30, 60 min. | |
| Recording Mode | Endless (Overwrite oldest data when capacity is full) or One Time (Stop recording when capacity is full) |
|
| LCD Display Items | Measurements, Recording Status, Battery Life Warning, etc. | |
| Communication Interfaces | Optical Communication (proprietary protocol) Infrared Communication (IrPHY 1.2 low power) |
|
| Power(*1) | Lithium Battery (LS14250) x 1 | |
| Battery Life(*2) | Approx. 4 years (2 years with Infrared Communication Enabled) | |
| Dimensions | H 62 mm x W 47 mm x D 19 mm (excluding protrusions and sensor) | |
| Weight | Approx. 54 g (including battery) |
Approx. 55 g (including battery / excluding sensor) |
| Operating Environment | Temperature: -40 to 80 °C | |
| Waterproof Capacity | IP67: Immersion proof | IP64: Splash proof (rated for use in daily life) (*3) |
| Accessories | - | Temperature Sensor (TR-5106) |
| Lithium Battery (LS14250), Strap, User's Manual (Warranty Included) | ||
| Data Collection Devices | Communication Port: TR-50U2, TR-50U Data Collector: TR-57DCi, TR-57U, RTR-57U |
|
| (*1) The included lithium battery (LS14250) is not sold in stores. Please purchase the optional battery set (TR-11P2) for replacement. (*2) Battery life depends upon the measuring environment, recording interval, and quality of the battery being used. When infrared communication function is enabled, battery life may be further shortened if the unit is used under the inverter type fluorescent lighting. (*3) This is the waterproof capacity of the data logger with the sensor connected. |
||
$159.00
TR-52i Optical Datalogger with External Sensor Probe and IR Communication—
$159.00
TR-52i Optical Datalogger with External Sensor Probe and IR Communication
Closeout. Brand New. All sales are final.
Our TR-5i Series data loggers are designed to measure and record temperature, voltage, 4-20mA, or pulse count. The body of the data loggers are water resistant and can be used in an environment of -40 °C to 80 °C. Moreover, battery-powered operation means the loggers can be placed anywhere without the need for AC power.
The data recorded by the loggers can be transfered to PC via separately sold "Communication Port TR-50U2" or "Data Collector TR-57DCi", whereby users can analyze the data and view in graph form.
Furthermore, our Data Collector TR-57DCi enables on-site data collection and viewing of data; no longer it is necessary to manually gather the data loggers.
The data recorded by the loggers can be transfered to PC via separately sold "Communication Port TR-50U2" or "Data Collector TR-57DCi", whereby users can analyze the data and view in graph form.
Furthermore, our Data Collector TR-57DCi enables on-site data collection and viewing of data; no longer it is necessary to manually gather the data loggers.
The TR-51i and TR-52i data loggers comply with EN12830, the European Standard regarding Temperature recorders for the transport, storage and distribution of chilled, frozen, deep-frozen/quick-frozen food and ice cream.
Specifications
| TR-51i | TR-52i | |
|---|---|---|
| Measurement Channels | Temperature 1ch (Internal) | Temperature 1ch (External) |
| Sensor | Thermistor | Thermistor |
| Measurement Units | °C, °F | °C, °F |
| Measurement Range | -40 to 80 °C | -60 to 155 °C |
| Responsiveness | Thermal Time Constant: Approx. 15 min. Response Time (90%): Approx. 35 min. |
Thermal Time Constant: Approx. 30 sec. (in air) Approx. 4 sec. (in agitated water) Response Time (90%): Approx. 80 sec. (in air) Approx. 7 sec. (in agitated water) |
| Accuracy | Avg. ±0.5 °C | Avg. ±0.3 °C [-20 to 80 °C] Avg. ±0.5 °C [-40 to -20 °C / 80 to 110 °C] Avg. ±1.0 °C [-60 to -40 °C/ 110 to 155 °C] |
| Measurement Resolution | 0.1 °C | |
| Logging Capacity | 16,000 readings | |
| Recording Interval | Select from 15 choices: 1, 2, 5, 10, 15, 20, 30 sec. or 1, 2, 5, 10, 15, 20, 30, 60 min. | |
| Recording Mode | Endless (Overwrite oldest data when capacity is full) or One Time (Stop recording when capacity is full) |
|
| LCD Display Items | Measurements, Recording Status, Battery Life Warning, etc. | |
| Communication Interfaces | Optical Communication (proprietary protocol) Infrared Communication (IrPHY 1.2 low power) |
|
| Power(*1) | Lithium Battery (LS14250) x 1 | |
| Battery Life(*2) | Approx. 4 years (2 years with Infrared Communication Enabled) | |
| Dimensions | H 62 mm x W 47 mm x D 19 mm (excluding protrusions and sensor) | |
| Weight | Approx. 54 g (including battery) |
Approx. 55 g (including battery / excluding sensor) |
| Operating Environment | Temperature: -40 to 80 °C | |
| Waterproof Capacity | IP67: Immersion proof | IP64: Splash proof (rated for use in daily life) (*3) |
| Accessories | - | Temperature Sensor (TR-5106) |
| Lithium Battery (LS14250), Strap, User's Manual (Warranty Included) | ||
| Data Collection Devices | Communication Port: TR-50U2, TR-50U Data Collector: TR-57DCi, TR-57U, RTR-57U |
|
| (*1) The included lithium battery (LS14250) is not sold in stores. Please purchase the optional battery set (TR-11P2) for replacement. (*2) Battery life depends upon the measuring environment, recording interval, and quality of the battery being used. When infrared communication function is enabled, battery life may be further shortened if the unit is used under the inverter type fluorescent lighting. (*3) This is the waterproof capacity of the data logger with the sensor connected. |
||
Product Information
Product Information
Shipping & Returns
Shipping & Returns
Description
Closeout. Brand New. All sales are final.
Our TR-5i Series data loggers are designed to measure and record temperature, voltage, 4-20mA, or pulse count. The body of the data loggers are water resistant and can be used in an environment of -40 °C to 80 °C. Moreover, battery-powered operation means the loggers can be placed anywhere without the need for AC power.
The data recorded by the loggers can be transfered to PC via separately sold "Communication Port TR-50U2" or "Data Collector TR-57DCi", whereby users can analyze the data and view in graph form.
Furthermore, our Data Collector TR-57DCi enables on-site data collection and viewing of data; no longer it is necessary to manually gather the data loggers.
The data recorded by the loggers can be transfered to PC via separately sold "Communication Port TR-50U2" or "Data Collector TR-57DCi", whereby users can analyze the data and view in graph form.
Furthermore, our Data Collector TR-57DCi enables on-site data collection and viewing of data; no longer it is necessary to manually gather the data loggers.
The TR-51i and TR-52i data loggers comply with EN12830, the European Standard regarding Temperature recorders for the transport, storage and distribution of chilled, frozen, deep-frozen/quick-frozen food and ice cream.
Specifications
| TR-51i | TR-52i | |
|---|---|---|
| Measurement Channels | Temperature 1ch (Internal) | Temperature 1ch (External) |
| Sensor | Thermistor | Thermistor |
| Measurement Units | °C, °F | °C, °F |
| Measurement Range | -40 to 80 °C | -60 to 155 °C |
| Responsiveness | Thermal Time Constant: Approx. 15 min. Response Time (90%): Approx. 35 min. |
Thermal Time Constant: Approx. 30 sec. (in air) Approx. 4 sec. (in agitated water) Response Time (90%): Approx. 80 sec. (in air) Approx. 7 sec. (in agitated water) |
| Accuracy | Avg. ±0.5 °C | Avg. ±0.3 °C [-20 to 80 °C] Avg. ±0.5 °C [-40 to -20 °C / 80 to 110 °C] Avg. ±1.0 °C [-60 to -40 °C/ 110 to 155 °C] |
| Measurement Resolution | 0.1 °C | |
| Logging Capacity | 16,000 readings | |
| Recording Interval | Select from 15 choices: 1, 2, 5, 10, 15, 20, 30 sec. or 1, 2, 5, 10, 15, 20, 30, 60 min. | |
| Recording Mode | Endless (Overwrite oldest data when capacity is full) or One Time (Stop recording when capacity is full) |
|
| LCD Display Items | Measurements, Recording Status, Battery Life Warning, etc. | |
| Communication Interfaces | Optical Communication (proprietary protocol) Infrared Communication (IrPHY 1.2 low power) |
|
| Power(*1) | Lithium Battery (LS14250) x 1 | |
| Battery Life(*2) | Approx. 4 years (2 years with Infrared Communication Enabled) | |
| Dimensions | H 62 mm x W 47 mm x D 19 mm (excluding protrusions and sensor) | |
| Weight | Approx. 54 g (including battery) |
Approx. 55 g (including battery / excluding sensor) |
| Operating Environment | Temperature: -40 to 80 °C | |
| Waterproof Capacity | IP67: Immersion proof | IP64: Splash proof (rated for use in daily life) (*3) |
| Accessories | - | Temperature Sensor (TR-5106) |
| Lithium Battery (LS14250), Strap, User's Manual (Warranty Included) | ||
| Data Collection Devices | Communication Port: TR-50U2, TR-50U Data Collector: TR-57DCi, TR-57U, RTR-57U |
|
| (*1) The included lithium battery (LS14250) is not sold in stores. Please purchase the optional battery set (TR-11P2) for replacement. (*2) Battery life depends upon the measuring environment, recording interval, and quality of the battery being used. When infrared communication function is enabled, battery life may be further shortened if the unit is used under the inverter type fluorescent lighting. (*3) This is the waterproof capacity of the data logger with the sensor connected. |
||